  Datasheet File OCR Text:
  film capacitors ? power factor correction dynamic and hybrid power factor controller series/type: BR7000-I-TH, BR7000-I-TH/s485 ordering code: b44066r7412e230/b44066r7612e230 date: march 2014 version: 1 ? epcos ag 2014. reproduction, publicati on and dissemination of this publicatio n, enclosures hereto and the information contained therein without epcos' pr ior express consent is prohibited. content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! please fill in the table and then change the color to "white". this ensures that the table disappears (invisible) for the customer pdf. don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! identification/classification 1 (header 1 + top left bar): film capacitors ? power factor correction identification/classification 2 (header 2 + bottom left header bar): dynamic and hybrid power factor controller ordering code: (top right header bar) b44066r7412e230/b44066r7612e230 series/type: (top right header bar) BR7000-I-TH, BR7000-I-TH/s485 preliminary data (optional): (if necessary) department: cap film p pm pfc date: march 2014 version: 1
film capacitors ? power factor co rrection b44066r7412e 230/b44066r7612e230 dynamic and hybrid power factor c ontroller BR7000-I-TH, BR7000-I-TH/s485 cap film p pm pfc march 2014 please read cautions and warnings and page 2 of 6 important notes at the end of this document . characteristics ? 12 transistor and 12 relay outputs ? direct triggering of up to 32 thyristor switches tsm-lc-s at the bus; bi-directional communication; design of self-monitoring dynamic systems with bus coupling (only version /s485) ? 20 pre-programmed control series ? control series editor ? full graphic display 128 x 64 pixel ? plain language menu ? 4-quadrant-operation ? display of multiple grid parameters ? display of harmonics (up to 33 rd ) ? display of distortion factor thd-v/thd-i ? display and control of temperature ? storage of maximum values ? storage of switching operations and times (relay outputs) ? manual and automatic operation ? zero voltage cut-off ? various error messages/alarm rely ? error storage ? interface rs485 for version -/s485 ? panel mounting 144 x 144 x 55 mm inputs ? operation voltage: 110 ? 230 v ac +/- 15% ? measuring voltage: 30 ? 440 v ac (l-n) / 50 ? 760 v ac (l-l) ? current: x:1a / x:5a ? standard serial interface (e.g. for firmware update) ? version ?/s485: 1 external input outputs ? 12 relay outputs ? 12 transistor outputs ? 1 relay output (alarm/fan) ? version -/s485: 1 message relay (free programmable) ? version -/s485: interface rs485
film capacitors ? power factor co rrection b44066r7412e 230/b44066r7612e230 dynamic and hybrid power factor c ontroller BR7000-I-TH, BR7000-I-TH/s485 cap film p pm pfc march 2014 please read cautions and warnings and page 3 of 6 important notes at the end of this document . measuring and display of following grid parameters ? voltage, current, frequency ? active, reactive and apparent power ? power factor, missing reactive power ? harmonics of voltage (up to 33 rd /even up to 16 th ) ? harmonic of current (up to 33 rd /even up to 16 th ) ? tdh-v, thd-i ? temperature ? well-arranged display of power factor and actual status of switching outputs ? display and storage of maximum values, switching operations and operation time (only static stages) ? display of harmonics as bar chart operation ? graphic display 164 x 64 dots with 8 lines maximum ? plain language menu in several languages ? optimum navigation in the menus via return (escape) button ? help-button for interactive help text version with interface (br7000-1-th/s485) ? additional potential free input (programmable) for ? switch over 2 nd target cos-phi ? triggering of a reactive power off-set ? additional potential free relay output (message relay) for ? switching of a fan ? display of error- or status messages (programmable) ? interface rs485 (modbus rtu) for ? direct triggering of up to 32 addressable thyristor switches tsm-lc-s with bi-directional communication ? imbedding of the controller into a network ? usage of software br7000-soft ? output of measured values in acsii-protocol ? internal battery-buffered clock for ? creation of time stamp of all recorded maximum values ? creation of time stamp for all error messages
film capacitors ? power factor co rrection b44066r7412e 230/b44066r7612e230 dynamic and hybrid power factor c ontroller BR7000-I-TH, BR7000-I-TH/s485 cap film p pm pfc march 2014 please read cautions and warnings and page 4 of 6 important notes at the end of this document . technical data and specifications operating voltage 110 ? 230 v ac +/- 15 %, 50 and 60 hz measuring voltage 30 ? 440 v ac (l-n); 50 ? 760 v ac (l-l); 50/60 hz measuring current x: 5 a / x: 1 a, selectable power consumption < 5 va sensitivity 50 ma/10 ma switching outputs relay outputs for capacitor contactors transistor outputs for thyristor switches 12 12 alarm relay 1 message relay 1 for version -/s485 only switching power of relays switching power of thyristors 250 v ac, 1000 w 24 v dc, 50 ma number of active outputs programmable operation and display display illuminated full graphic display 128 x 64 dots menu languages cz/en/es/fr/ger/nl/pl/pt/ru/tr freely editable control series 1 via editor control control principle sequential switching, circle switching, intelligent switching behavior, 4-quadrant operation operation modes dynamic or hybrid pf-controller target cos- 0.1 inductive up to 0.1 capacitive adjustable switch on time (dynamic/relay) 20 ? 1000 ms / 1 sec ? 20 min switch off time 20 ? 1000 ms / 1 sec ? 20 min discharge time 20 ? 1000 ms / 1 sec ? 20 min manual operation yes fixed steps/skip steps programmable zero voltage release standard display/display functions display of grid parameters cos- , v, i , f, w, q, p, s, q, thd-v, thd-i display of harmonics 3 rd to 33 rd harmonics of v and i; even harmonics up to 16 th accuracy current/voltage: 1% active, apparent and reactive power: 2% integrated help function contex t dependent (german/english)
film capacitors ? power factor co rrection b44066r7412e 230/b44066r7612e230 dynamic and hybrid power factor c ontroller BR7000-I-TH, BR7000-I-TH/s485 cap film p pm pfc march 2014 please read cautions and warnings and page 5 of 6 important notes at the end of this document . cautions and warnings controller hunting: when putting the capacitor bank into operation, it is required to avoid needless switching cycles (means permanent switching on and off of steps without significant change of consumer load). this so called ?controller hunting? would increase the number of switching operations of the connected contactors and capacitors and decrease the expected life cycle (wear out) and, in worst case, capacitor bursting and fire, etc . this can be avoided by a proper programming of the BR7000-I-TH and BR7000-I-TH/s485 with the actual sy stem parameters (current transformer prim. and sec., first kvar step, control series, switching time). u please read cautions information about pfc capacitors and cautions as well as installation and maintenance instructions in the actual version of the product profile power factor correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. the actual product profile is available at www.epcos.com/publications. information given in the pfc-product profile and values given in the data sheet reflect typical specifications. you are kindly requested to approve our product specifications or request our approval for your specification before ordering. note for detailed information about pfc capacitors and cautions, refer to the latest version of epcos pfc product profile. storage function storage of maximum values voltage, current, ac tive/reactive/apparent power, temperature, thd-v, thd-i storage of switching operations each output c an be reset separately (only contactor stages) storage of operation time each capacitor can be reset separately (only contactor stages) error storage error register in plain language temperature monitoring monitoring automatic step switch off temperature measuring range -30 ? +100 c casing panel mounted instrument din 43700, 144 x 144 x 55 mm weight 1 kg ambient operating temperature -20 ? +60 c protection class accord. din 40050 front: ip54, rear: ip 20 safety regulations iec 601010-1 interference resistance iec 61000-6-2; en 61326 emc-interference iec 61000-4-2; iec61000-4-4 ordering codes BR7000-I-TH (without interface) BR7000-I-TH/s485 (with interface rs485) b44066r7412e230 b44066r7612e230
important notes page 6 of 6 the following applies to all products named in this publication: 1. some parts of this publication contain statements about the suitability of our products for certain areas of application . these statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. we nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. as a rule, epcos is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. for these reasons , it is always ultimately incumbent on the customer to check and decide whether an epcos product with the properties described in the product specification is suitable for use in a particular customer application. 2. we also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. in customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must theref ore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. the warnings, cautions and product-specific notes must be observed. 4. in order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous) . useful information on this will be found in our material data sheets on the internet (www.epcos.com/material). should you have any more detailed questions, please contact our sales offices. 5. we constantly strive to improve our products. consequently, the products described in this publication may change from time to time . the same is true of the corresponding product specifications. please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. we also reserve the right to discontinue production and delivery of products . consequently, we cannot guarantee that all products named in this publication will always be available. the aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. unless otherwise agreed in individual contracts, all orders are subject to the current version of the ?general terms of delivery for products and services in the electrical industry? published by the german electrical and electronics industry association (zvei) . 7. the trade names epcos, baoke, alu-x, ceradiode, ceralink, csmp, cssp, ctvs, deltacap, digisimic, dssp, filtercap, formfit, miniblue, minicell, mkd, mkk, mlsc, motorcap, pcc, phasecap, phasecube, phasemod, phicap, siferrit, sifi, sikorel, silvercap, simdad, simic, simid, sineformer, siov, si p5d, sip5k, thermofuse, windcap are trademarks registered or pending in europe and in other countries. further information will be found on the internet at www.epcos.com/trademarks.


▲Up To Search▲   

 
Price & Availability of BR7000-I-TH

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X